-
Downstream Modification of Mercury in Diverse River Systems Underscores the...
Abstract: Fish consumption advisories for mercury (Hg) are common in rivers, highlighting connections between landscape sources of Hg and downstream fluvial ecosystems. Though... -
Quantifying Meltwater Sources and Contaminant Fluxes from the Athabasca...
Abstract: Glaciers are retreating across the Canadian Rocky Mountains. As this ice volume is lost, trace elements, nutrients, and other contaminants, accumulated from millennia... -
Severe western Canadian wildfire affects water quality even at large basin scales
Highlights •Large rivers show wildfire water quality signatures after precipitation events. •Continuous monitoring captures short-term wildfire impacts on river water quality.... -
Selection of both habitat and genes in specialized and endangered caribou
Genetic mechanisms determining habitat selection and specialization of individuals within species have been hypothesized, but not tested at the appropriate individual level in... -
Increasing fire frequency and severity will increase habitat loss for a...
Climate change will lead to more frequent and more severe fires in some areas of boreal forests, affecting the distribution and availability of late-successional forest... -
Genomic legacy of migration in endangered caribou
Wide-ranging animals, including migratory species, are significantly threatened by the effects of habitat fragmentation and habitat loss. In the case of terrestrial mammals,... -
Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer
This document will outline specifics with regards to portable sampling analysis utilizing and operating the Thermo-Miran SapphIRE. The intent is to provide operating procedures... -
Standard Operating Procedure for Measurement of Oxides of Nitrogen in by...
To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality index reporting and to meet the requirements for inclusion of the data... -
Standard Operating Procedure for Air Dryers
The Puregas and Bendix model air dryers are designed to effectively remove moisture or other unwanted components from a compressed air stream. They separate the various... -
Standard Operating Procedure for Measurement of Barometric Pressure Using...
This procedure describes the operation and maintenance of the Vaisala PTB 220 digital barometer. This sensor can be used for handheld measurements, and can be connected to a... -
Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator
This procedure is intended to describe the operations of the Dasibi model 5008 calibrator. -
Standard Operating Procedure for Fluke Portable Voltage Calibrator
This procedure describes the operation and maintenance of the Fluke Model 515A portable voltage calibrator. This device is used to generate accurate AC and DC voltages and... -
Standard Operating Procedure for Flow Measurement Using a Primary Flow Meter
This procedure describes the operation and maintenance of the BIOS DC-2 flow meter. This device is used to measure air flow rate either from vacuum or pressure flow sources.... -
Standard Operating Procedure for R&R Environmental Devices Model 200 Zero Span Module
Daily data of instrument baseline and upscale response is required to verify instrument performance. The R & R Model 200 provides a stable span source. To meet the... -
Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas...
To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality index reporting and to meet the requirements for inclusion of the data... -
Standard Operating Procedure for Measurement of Particulate Matter in...
To obtain timely data for the purpose of air quality assessment, air quality trend reporting and to meet the requirements for inclusion of the data in provincial and national... -
Standard Operating Procedure for High-Volume Polyurethane Foam Sampler
For the purpose of collection of ambient air samples for determination of polyaromatic hydrocarbons (PAH), Polychlorinated biphenols (PCB’s), dioxins and furans, and pesticides... -
Standard Operating Procedure for Measurement of Ethylene (C2H4) in Ambient...
To obtain timely data for the purpose of air quality assessment, air quality trend reporting and to meet the requirements for inclusion of the data in provincial and national... -
Standard Operating Procedure for Elemental and Organic Carbon (EC and OC)...
To obtain timely data for the purpose of air quality assessment, air quality trend reporting and to meet the requirements for inclusion of the data in provincial and national... -
Standard Operating Procedure for Measurement of CO in Ambient Air by Gas...
To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality index reporting and to meet the requirements for inclusion of the data...