-
Standard Operating Procedures for Water Quality Data Management and Database...
The Athabasca Arctic (AA) Watershed uses a data-management system called ACBIS (Aquatic Chemistry and Biology Information System) to store, track, verify, and distribute data to... -
LICA SOP-005 Ozone
Ozone analyzers operate on the principle that ozone (O3) molecules absorbUV light at a wavelength of 254 nm. The degree to which the UV light isabsorbed is directly related to... -
Joint Oil Sands Monitoring, Environment Canada Cause and Effects Monitoring...
This Standard Operating Procedure identifies preparatory steps that must be taken prior to the field season of the Environment Canada (EC) Cause and Effects Monitoring Program... -
Standard Operating Procedure for MAML System
This SOP is intended to provide instruction on operation of the Mobile Air Monitoring Laboratory (MAML) as it relates to air quality monitoring operations and the data generated... -
Standard Operating Procedure for Zero-Air Generators
Continuous ambient air analyzers require multipoint calibrations on a routine monthly basis and after major maintenance is completed. This procedure describes the role of Zero-... -
Standard Operating Procedure for Measurement of Oxides of Nitrogen in by...
To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality index reporting and to meet the requirements for inclusion of the data... -
Standard Operating Procedure for Measurement of Barometric Pressure Using...
This procedure describes the operation and maintenance of the Vaisala PTB 220 digital barometer. This sensor can be used for handheld measurements, and can be connected to a... -
Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator
This procedure is intended to describe the operations of the Dasibi model 5008 calibrator. -
Standard Operating Procedure for Fluke Portable Voltage Calibrator
This procedure describes the operation and maintenance of the Fluke Model 515A portable voltage calibrator. This device is used to generate accurate AC and DC voltages and... -
Standard Operating Procedure for Flow Measurement Using a Primary Flow Meter
This procedure describes the operation and maintenance of the BIOS DC-2 flow meter. This device is used to measure air flow rate either from vacuum or pressure flow sources.... -
Standard Operating Procedure for R&R Environmental Devices Model 200 Zero Span Module
Daily data of instrument baseline and upscale response is required to verify instrument performance. The R & R Model 200 provides a stable span source. To meet the... -
Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas...
To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality index reporting and to meet the requirements for inclusion of the data... -
Standard Operating Procedure for Measurement of Particulate Matter in...
To obtain timely data for the purpose of air quality assessment, air quality trend reporting and to meet the requirements for inclusion of the data in provincial and national... -
Standard Operating Procedure for Measurement of Ethylene (C2H4) in Ambient...
To obtain timely data for the purpose of air quality assessment, air quality trend reporting and to meet the requirements for inclusion of the data in provincial and national... -
Standard Operating Procedure for Elemental and Organic Carbon (EC and OC)...
To obtain timely data for the purpose of air quality assessment, air quality trend reporting and to meet the requirements for inclusion of the data in provincial and national... -
Standard Operating Procedure for Measurement of CO in Ambient Air by Gas...
To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality index reporting and to meet the requirements for inclusion of the data... -
Standard Operating Procedure for Measurement of Methane/Non- Methane...
To obtain timely data for the purpose of air quality assessment, air quality trend reporting, and to meet the requirements for inclusion of the data in provincial and national... -
Standard Operating Procedure for Measurement of Ozone in Ambient Air by...
To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality index reporting and to meet the requirements for inclusion of the data... -
Standard Operating Procedure for Measurement of SO2 by SO2 fluorescence
To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality index reporting and to meet the requirements for inclusion of the data... -
Standard Operating Procedure for Measurement of Total Hydrocarbon Using a...
To obtain timely data for the purpose of air quality assessment, air quality trend reporting, and to meet the requirements for inclusion of the data in provincial and national...